TM 5-3805-298-23-1
0121
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 28. Test for Shorted Wiring
Condenser Fan(s) Do Not
Operate When the Heater A/C Harness.
1. Remove A/C BKR circuit breaker
Switch Is in A/C Position -
(TM 5-3805-298-10).
Continued
Continuity Proceed to Test Step 29.
(WP 0174), test for continuity
No Continuity Replace A/C
between connector C-C33
condenser fans (WP 0417).
Proceed to Test Step 33.
and ground.
Test Step 29. Test for Shorted Wiring
Harness.
1. Remove right lower cab access
panels (WP 0347).
2. Disconnect connector M-C1
Figure 56).
Continuity Proceed to Test Step 30.
(WP 0174), test for continuity
No Continuity Replace lower cab
between connector M-C1
wiring harness (WP 0291).
Proceed to Test Step 33.
and ground.
Test Step 30. Test for Shorted Air
Conditioning Condenser Fans
Wiring Harness.
1. Disconnect connector M-C15
Figure 130).
Continuity Replace air conditioning
(WP 0174), test for continuity
condenser fans wiring harness
between connector MA-C2
(WP 0418).
Proceed to Test Step 33.
and terminal C.
No Continuity Replace rear frame
wiring harness (WP 0295).
Proceed to Test Step 33.
Test Step 31. Test for Voltage at
Primary A/C Condenser Fan 1.
1. Disconnect connector MA-C1
2. Turn battery disconnect switch ON
and start the machine (TM 5-3805-
298-10).
3. Turn heater A/C switch to A/C ON
position (TM 5-3805-298-10).
0121-18