Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1240    1241    1242    1243    1244  1245  1246    1247    1248    1249    1250  
img
.
TM 5-3805-298-23-1
0121
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Turn heater A/C switch to A/C ON
Condenser Fan(s) Do Not
position (TM 5-3805-298-10).
Operate When the Heater A/
3. Turn heater control knob to
C Switch Is in A/C Position -
maximum cold (TM 5-3805-298-
Continued
10).
WARNING
Flying particles may be ejected while fans are in operation. Wear eye
protection and gloves while performing inspection.
Failure to follow this warning may cause injury to personnel.
4. Visually inspect primary condenser
All Three A/C Condenser Fans
Operate Proceed to Test Step 33.
fans (Figure 4, Item 1) and
auxiliary fan (Figure 4, Item 2)
Both Primary A/C Condenser Fans
operation (TM 5-3805-298-10).
Do Not Operate Proceed to Test
Step 28.