TM 5-3805-298-23-1
0122
Table 1. Dome Light Does Not Operate.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Dome Light Does Not
Operate
Always inspect wiring harness connectors that are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure and
that all connections are in good condition. If a problem with the
connection is found, correct the problem and verify that this malfunction
or diagnostic code is active before performing this procedure.
Perform open or short-circuit test at each wiring harness connection to
identify the correct harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
Test Step 1. Test for Voltage at Dome
Light.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Remove dome light (TM 5-3805-
298-10).
3. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-298-10).
4. Turn the military light switch to
Stop Light position (TM 5-3805-
298-10).
5. Turn dome light switch to ON
position (TM 5-3805-298-10).
Voltage 18 to 26 V Replace dome
(WP 0174), test for voltage
light bulb (TM 5-3805-298-10).
Proceed to Test Step 23.
Figure 138) terminal 1 and
Voltage Less Than 18 V Proceed to
terminal 2 (ground).
step 7.
Voltage 18 to 26 V Replace dome
(WP 0174), test for voltage
light assembly (TM 5-3805-298-10).
between connector G-Dome
Proceed to Test Step 23.
Voltage Less Than 18 V Proceed to
and terminal 2 (ground).
Test Step 2.
Test Step 2. Test Horn Operation.
Push the horn button and take note of
Horn Operates Proceed to Test
horn operation (TM 5-3805-298-10).
Step 3.
Horn Does Not Operate Proceed to
Test Step 4.