TM 5-3805-298-23-2
0140
Table 1. Work Area Vision System (WAVS) Does Not Operate Properly - Continued.
0140
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Disconnect jumper wire between
Work Area Vision System
terminal 1 and terminal 2 of
(WAVS) Does Not Operate
camera cable 1 connector
Properly - Continued
(WP 0012, Figure 201).
8. Connect jumper wire between
terminal 3 and terminal 4 of
camera cable 1 connector
(WP 0012, Figure 201).
Resistance 5.0 Ohms or Less
Proceed to Test Step 4.
between camera cable 1
connector (WP 0012, Figure 200)
Replace middle camera communication
terminal 3 and terminal 4.
cable (WP 0268).
Proceed to Test Step 15.
Test Step 4. Test for Open WAVS
Camera Communication Cable 2.
2. Disconnect camera cable 2
connector (WP 0012, Figure 203)
from camera cable connector.
3. Install a jumper wire between
terminal 1 and terminal 2 of
camera cable 2 connector
(WP 0012, Figure 203).
Resistance 5.0 Ohms or Less
Proceed to step 5.
between camera cable 2
connector (WP 0012, Figure 202)
Replace rear camera communication
terminal 1 and terminal 2.
cable (WP 0268).
Proceed to Test Step 15.
5. Remove jumper wire from terminal
1 and terminal 2 of camera cable 2
connector (WP 0012, Figure 203).
6. Install a jumper wire between
terminal 3 and terminal 4 of
camera cable 2 connector
(WP 0012, Figure 203).
Resistance 5.0 Ohms or Less
Proceed to Test Step 5.
between camera cable 2
connector (WP 0012, Figure 202)
Replace rear camera communication
terminal 3 and terminal 4.
cable (WP 0268).
Proceed to Test Step 15.
0140-4