TM 5-3805-298-23-2
0140
Table 1. Work Area Vision System (WAVS) Does Not Operate Properly - Continued.
0140
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Test for Voltage at WAVS
Work Area Vision System
Camera Cable 2.
(WAVS) Does Not Operate
1. Remove jumper wire from terminal
Properly - Continued
3 and terminal 4 of camera cable 2
connector (WP 0012,
Figure 203).
2. Connect camera cable 1 connector
(WP 0012, Figure 200) to camera
display cable connector.
3. Connect camera cable 1 connector
(WP 0012, Figure 201) to camera
cable 2 connector (WP 0012,
Figure 202).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-298-10).
Voltage 11.5 to 13.2 V Replace
camera (WP 0268).
between camera cable 2
Proceed to Test Step 6.
connector (WP 0012, Figure 203)
Voltage Less Than 11.5 V Replace
terminal 3 and terminal 4 (ground).
camera display screen (WP 0267).
Proceed to Test Step 15.
Test Step 6. Verify Malfunction Is
Resolved.
1. Ensure all harness connectors and
cable connectors are connected.
2. Turn the military light switch to Ser.
Drive position and lower switch in
OFF (TM 5-3805-298-10).
3. Observe operation of WAVS
Display is Normal Troubleshooting
(TM 5-3805-298-10).
complete.
No Display Replace camera display
screen (WP 0267).
Proceed to Test Step 15.
0140-5