Table 1. Arctic Troubleshooting Procedures - Continued.
Table 1. Arctic Troubleshooting Procedures - Continued.

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  318    319    320    321    322  323  324    325    326    327    328  
img
. . . . . .
TM 5-3805-298-23-4
0395
Table 1. Arctic Troubleshooting Procedures - Continued.
0395
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Arctic Heater Does Not
5. Turn arctic heater switch ON
Arctic Fuel Metering Pump Turns
Heat Up - Continued
(TM 5-3805-298-10) and verify
ON - Proceed to step 6.
arctic fuel metering pump is
Arctic Fuel Metering Pump Does Not
activated.
Turn ON - Proceed to Arctic Heater
Does Not Turn On in this work package.
6. Perform Arctic Heater Fuel Flow
Fuel Flow Between 6.5 mL and
Test (WP 0396).
8.25 mL - Arctic fuel metering pump ok,
replace arctic heater (WP 0402).
Proceed to Test Step 2.
Fuel Flow Greater Than 8.25 mL -
Replace arctic fuel metering pump
(WP 0404).
Proceed to Test Step 2.
Fuel Flow Less Than 6.5 mL -
Proceed to step 7.
7. Inspect fuel metering pump
Arctic Fuel Metering Pump Hoses
(Figure 3, Item 3), and hose
and Clamps OK - Replace fuel
(Figure 3, Items 1, and 5) for sharp
metering pump (WP 0404).
bends, kinks, restrictions, damage,
Proceed to Test Step 2.
and loose clamps (Figure 3,
Arctic Fuel Metering Hose Bent,
Items 2 and 4).
Kinked, Restricted, or Loose Clamps
- Tighten clamps, or replace arctic fuel
metering pump hose (WP 0404).
Proceed to Test Step 2.
Figure 3. Fuel Metering Pump and Hose.
0395
0395-4