TM 5-3805-298-23-4
0395
Table 1. Arctic Troubleshooting Procedures - Continued.
0395
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Arctic Heater Does Not
5. Turn arctic heater switch ON
Arctic Fuel Metering Pump Turns
Heat Up - Continued
(TM 5-3805-298-10) and verify
ON - Proceed to step 6.
arctic fuel metering pump is
Arctic Fuel Metering Pump Does Not
activated.
Turn ON - Proceed to Arctic Heater
Does Not Turn On in this work package.
6. Perform Arctic Heater Fuel Flow
Fuel Flow Between 6.5 mL and
8.25 mL - Arctic fuel metering pump ok,
Proceed to Test Step 2.
Fuel Flow Greater Than 8.25 mL -
Replace arctic fuel metering pump
Proceed to Test Step 2.
Fuel Flow Less Than 6.5 mL -
Proceed to step 7.
7. Inspect fuel metering pump
Arctic Fuel Metering Pump Hoses
(Figure 3, Item 3), and hose
and Clamps OK - Replace fuel
(Figure 3, Items 1, and 5) for sharp
bends, kinks, restrictions, damage,
Proceed to Test Step 2.
and loose clamps (Figure 3,
Arctic Fuel Metering Hose Bent,
Items 2 and 4).
Kinked, Restricted, or Loose Clamps
- Tighten clamps, or replace arctic fuel
Proceed to Test Step 2.
Figure 3. Fuel Metering Pump and Hose.
0395