TM 5-3805-298-23-4
0395
Table 1. Arctic Troubleshooting Procedures - Continued.
0395
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Arctic Heater Turns ON
3. Inspect arctic heater exhaust tube
Arctic Heater Exhaust Tube OK -
and Shuts Down -
(Figure 5, Item 2) for kinks, bends,
Proceed to step 4.
Continued
damage, and restrictions.
Bent or Damaged - Replace arctic
Proceed to Test Step 2.
Arctic Heater Exhaust Tube
Restricted - Clear restriction from arctic
heater exhaust tube.
Proceed to Test Step 2.
4. Inspect arctic heater fresh air
Arctic Heater Fresh Air Intake OK -
intake port (Figure 5, Item 1) for
Proceed to step 5.
damage or restrictions.
Arctic Heater Fresh Air Intake
Damaged - Replace arctic heater
Proceed to Test Step 2.
Arctic Heater Fresh Air Intake
Restricted - Clear restriction from arctic
heater fresh air intake.
Proceed to Test Step 2.
Figure 5. Arctic Heater Intake Port and Exhaust Tube.
0395