TM 5-3805-298-23-4
0395
Table 1. Arctic Troubleshooting Procedures - Continued.
0395
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Arctic Heater Turns ON
Test Step 2. Verify Symptom Is
and Shuts Down -
Resolved.
Continued
1. Install right lower cab access
panels (WP 0347).
2. Turn arctic heater switch ON
Arctic Heater Turns ON and Heats
(TM 5-3805-298-10) and verify
Up - Troubleshooting complete.
arctic heater turns on.
Arctic Heater Turns On But Shuts
Down - Replace arctic heater
3. Arctic Heater Does Not
Test Step 1. Inspect the Arctic
Turn ON
Heater Fuse.
1. Remove Arctic Heater 20a fuse
(TM 5-3805-298-10).
(WP 0174), measure resistance
Install arctic heater fuse (TM 5-3805-
between fuse terminals.
298-10).
Proceed to Test Step 2.
Install new arctic heater fuse (TM 5-
3805-298-10).
Proceed to Test Step 5.
Test Step 2. Test Arctic Heater
Voltage, Ground, and Signal
Circuits.
1. Remove right lower cab access
panels (WP 0347).
2. Disconnect arctic heater wiring
harness connector HJ-C2
(WP 0012, Figure 229) from arctic
heater (WP 0012, Figure 229).
3. Turn battery disconnect switch to
the ON position (TM 5-3805-298-
10).
4. Turn arctic heater switch to the ON
position (TM 5-3805-298-10).
Voltage 18 - 26 V - Proceed to step 6.
(WP 0174), test for voltage
Voltage Less than 18 V - Proceed to
between arctic heater wiring
Test Step 6.
harness connector HJ-C2 terminal
A3 (WP 0012, Figure 229) and
machine ground.