TM 5-3805-298-23-4
0395
Table 1. Arctic Troubleshooting Procedures - Continued.
0395
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Arctic Heater Does Not
Test Step 8. Test Arctic Heater Signal
Turn ON - Continued
Circuit for an Open.
1. Turn battery disconnect switch to
the OFF position (TM 5-3805-298-
10).
2. Remove four screws (Figure 7,
Item 2) and RH console switch
cover (Figure 7, Item 1) from RH
console (Figure 7, Item 3).
Figure 7. Right Hand Console.
0395
3. Disconnect lower cab wiring
harness B+ (brown wire) spade
terminal (Figure 8, Item 3) from
arctic heater switch (Figure 8,
Item 2).
4. Turn battery disconnect switch to
the ON position (TM 5-3805-298-
10).
Voltage 18 - 26 V - Proceed to step 6.
(WP 0174), test for voltage
Voltage Less Than 18 V - Replace
between lower cab wiring harness
lower cab wiring harness (WP 0291).
B+ terminal (Figure 8, Item 3) and
Proceed to Test Step 9.
machine ground.
6. Turn battery disconnect switch to
the OFF position (TM 5-3805-298-
10).