TM 5-3805-298-23-4
0396
MEASURING FUEL FLOW
000396
Figure 1. Measuring Fuel Flow.
0396
1. Place fuel pressure line (Figure 1, Item 2) from metering pump (Figure 1, Item 1) into beaker (Figure 1, Item 4).
2. Turn the arctic heater (Figure 1, Item 3) ON (TM 5-3805-298-10) and wait until metering pump (Figure 1,
Item 1) starts pumping fuel.
3. Hold beaker (Figure 1, Item 4) at level of arctic heater (Figure 1, Item 3) for duration of test.
NOTE
Metering pump will automatically stop pumping fuel after 68 seconds.
4. Once metering pump (Figure 1, Item 1) stops pumping fuel, turn arctic heater (Figure 1, Item 3) OFF
(TM 5-3805-298-10).
5. Connect fuel pressure line (Figure 1, Item 2) to arctic heater (Figure 1, Item 3).
6. Return to troubleshooting.
END OF TASK
END OF WORK PACKAGE