Figure 4. Charging Station Hook-Up.
A/C COMPRESSOR AND MOUNTING BRACKET REPLACEMENT

Field Maintenance Manual For 924H Wheel Loader -4 Page Navigation
  452    453    454    455    456  457  458    459    460    461    462  
img
.
TM 5-3805-298-23-4
0405
A/C SYSTEM PERFORMANCE TEST CONTINUED
000405
NOTE
Pressure Range Table is for reference only.
Pressures listed are before clutch disengagement.
Table 1. Pressure Range Table.
0405
Ambient Air Temperature 
Discharge (High Side) Pressure 
Suction (Low Side) Pressure 
F (C)
psi (kPa)
psi (kPa)
70F (21C)
120 to 190 (820 to 1,300)
10 to 20 (70 to 138)
80F (27C)
140 to 210 (950 to 1,450)
10 to 25 (70 to 173)
90F (32C)
170 to 240 (1,175 to 1,650)
15 to 30 (105 to 210)
100F (38C)
190 to 270 (1,300 to 1,850)
15 to 30 (105 to 210)
110F (43C)
210 to 300 (1,450 to 2,075)
15 to 30 (105 to 210)
END OF TASK
END OF WORK PACKAGE