TM 5-3805-298-23-4
0412
REFRIGERANT DRYER INLET HOSE REMOVAL
000412
NOTE
Note routing of hose to aid installation.
Note quantity and position of tiedown straps to aid installation.
Tag and mark hose to aid installation.
Cap or plug hose end and open port to protect against contamination.
1. Remove air cleaner housing and bracket (WP 0204).
2. Remove tiedown straps (Figure 14, Item 6) from refrigerant dryer inlet hose (Figure 14, Item 5) and auxiliary air
conditioning condenser fan wiring harness (Figure 14, Item 4). Discard tiedown straps.
3. Loosen tube nut (Figure 14, Item 3) and remove refrigerant dryer inlet hose (Figure 14, Item 5) and O-ring
(Figure 14, Item 2) from auxiliary refrigerant condenser (Figure 14, Item 1). Discard O-ring.
Figure 14. Refrigerant Dryer Inlet Hose.
0412