TM 5-3805-298-23-4
0419
REMOVAL CONTINUED
NOTE
Note routing of tube to aid installation.
Tag and mark tube and fitting to aid installation.
Cap or plug tube end and fitting to protect against contamination.
17. Remove nut (Figure 6, Item 7), washer (Figure 6, Item 6), P-clamp (Figure 6, Item 5), bolt (Figure 6, Item 11)
washer (Figure 6, Item 10), P-clamp (Figure 6, Item 8) from bracket (Figure 6, Item 9).
18. Remove two P-clamps (Figure 6, Items 5 and 8) from two lines (Figure 6, Item 4).
19. Loosen two tube nuts (Figure 6, Item 3) and remove two lines (Figure 6, Item 4) and O-rings (Figure 6, Item 2)
from auxiliary air conditioning condenser (Figure 6, Item 1). Discard O-rings.
20. Loosen tube nut (Figure 6, Item 13) and remove elbow fitting (Figure 6, Item 12) and O-ring (Figure 6, Item 14)
from auxiliary air conditioning condenser (Figure 6, Item 1). Discard O-ring.
Figure 6. Auxiliary Air Conditioning Condenser Lines.
0419
END OF TASK
CLEANING AND INSPECTION
000419
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK