TM 5-3805-298-23-4
0419
INSTALLATION CONTINUED
12. With assistance, position auxiliary air conditioning condenser guard (Figure 9, Item 3) on machine.
13. Install four washers (Figure 9, Item 9) and bolts (Figure 9, Item 10) on auxiliary air conditioning condenser
guard (Figure 9, Item 3).
14. Install three washers (Figure 9, Item 8), bolts (Figure 9, Item 7), washer (Figure 9, Item 6), and nuts
(Figure 9, Item 5) on auxiliary air conditioning condenser guard (Figure 9, Item 3).
15. Install four washers (Figure 9, Item 2) and bolts (Figure 9, Item 1) on auxiliary air conditioning condenser guard
(Figure 9, Item 3) and air conditioning condenser (Figure 9, Item 4).
Figure 9. Auxiliary Air Conditioning Condenser Plates.
0419