TM 5-3805-298-23-4
0419
INSTALLATION CONTINUED
NOTE
Install wiring harness connectors and route wiring harness as noted during removal.
Install tiedown straps as noted during removal.
16. Position auxiliary air conditioning condenser fan wiring harness (Figure 10, Item 2) on machine.
17. Connect auxiliary air conditioning fan wiring harness connector (Figure 10, Item 3) on auxiliary condenser fan
relay (Figure 10, Item 4).
18. Connect auxiliary air conditioning fan wiring harness connector (Figure 10, Item 5) on auxiliary condenser fan
connector (Figure 10, Item 6).
19. Install new tiedown straps (Figure 10, Item 1) on auxiliary air conditioning condenser fan wiring harness
(Figure 10, Item 2).
Figure 10. Auxiliary Air Conditioning Condenser Fan Wiring Harness.
0419