Table 1. Ride Control Does Not Operate Correctly - Continued.
Table 1. Ride Control Does Not Operate Correctly - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  1035    1036    1037    1038    1039  1040  1041    1042    1043    1044    1045  
img
. . . . . . .
TM 5-2420-231-23-1
0083
Table 1. Ride Control Does Not Operate Correctly - Continued.
083
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 7. Test for Shorted Ride
Ride Control Does Not
Control Switch Wiring Harness.
Operate Correctly -
Continued
1. Remove two screws (Figure 5,
Item 2) from bezel (Figure 5, Item
1) and pull bezel (Figure 5, Item 1)
away from instrument panel right-
side cover (Figure 5, Item 3).
Figure 5. Blower Fan Switch and Bezel.
0083
2. Disconnect side options wiring har-
ness connector (WP 0007, Figure
196) from ride control switch con-
nector (WP 0007, Figure 197).
3. Using a digital multimeter, test for
Continuity - Proceed to Test Step 8.
continuity between side options
No Continuity - Install new ride control
wiring harness connector (WP
fuse (TM 5-2420-231-10).
0007, Figure 196) terminals 2 and
Replace ride control solenoid valves
machine ground. There should be
(WP 0254).
no continuity.
Proceed to Test Step 14.
Test Step 8. Test for Shorted Side
Options Wiring Harness.
1. Disconnect side options wiring har-
ness connector (WP 0007, Figure
44) from side console wiring har-
ness connector (WP 0007, Figure
45).
0083-7