Table 1. Ride Control Does Not Operate Correctly - Continued.
083
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 12. Test Right Solenoid
Ride Control Does Not
Valve for Ride Control.
Operate Correctly -
Continued
1. Perform right solenoid valve for
Pressure Gauge Reads 0 psi or No
ride control (accumulator) test for
Greater Than 25 psi - Proceed to step
loader lift in the raised position
2.
Pressure Gauge Reads Greater Than
25 psi - Replace right ride control
Proceed to Test Step 14.
2. Perform right solenoid valve for
Pressure Gauge Reads At Least 500
ride control (accumulator) test for
psi - Proceed to Test Step 14.
loader lift in the lowered position
Pressure Gauge Reads Less Than
500 psi - Replace right ride control
Proceed to Test Step 14.
Test Step 13. Test Left Solenoid
Valve for Ride Control.
Perform left solenoid valve for ride
Bucket Cannot Raise Machine -
control (tank) test for loader lift in the
Proceed to Test Step 14.
Bucket Raises Machine - Replace left
ride control solenoid valve (WP 0254).
Proceed to Test Step 14.
Test Step 14. Verify That Symptom Is
Resolved.
1. Ensure all wiring harness connec-
tors are reconnected.
2. Start and operate machine (TM 5-
2420-231-10).
3. Lower loader bucket to or near
ground (TM 5-2420-231-10).
4. Turn light control switch to the
SER. DRIVE position (TM 5-2420-
231-10).
Ride Control Indicator On - Proceed
5. Place ride control switch in the on
to step 6.
position (TM 5-2420-231-10) and
Ride Control Indicator Off - Repeat
observe ride control indicator.
troubleshooting from the beginning.