TM 5-2420-231-23-1
0086
FLOWMETER CONNECTION AND FLOW REGULATOR PRESSURE TEST CONTINUED
5. Remove hydraulic tank cap (Figure 4, Item 1).
6. Remove pressure testing adapter (Figure 2, Item 1) from pump EF port (Figure 2, Item 2).
Figure 2. EF Port.
0086
7. Connect flowmeter inlet (input) hose (Figure 3, Item 1) to EF port (Figure 3, Item 2).
Figure 3. Flowmeter Inlet Hose.