TM 5-2420-231-23-1
0086
LARGE AND SMALL HYDRAULIC OIL PUMP EFFICIENCY TEST CONTINUED
8. Remove two screws (Figure 29, Item 3) and screen (Figure 29, Item 4) from hydraulic reservoir
(Figure 29, Item 5).
9. Insert outlet hose (Figure 29, Item 2) until it touches bottom of hydraulic reservoir (Figure 29, Item 5) and
secure hose in place.
Figure 29. Hydraulic Reservoir.
0086
10. Connect inlet hose (Figure 30, Item 1) and outlet hose (Figure 30, Item 2) to flowmeter (Figure 30, Item 3).
Figure 30. Flowmeter Connections.
0086