TM 5-2420-231-23-1
0086
PILOT CONTROL VALVE TEST CONTINUED
7. Remove two screws (Figure 34, Item 3) and screen (Figure 34, Item 4) from hydraulic reservoir
(Figure 34, Item 5).
8. Insert outlet hose (Figure 34, Item 2) until it touches bottom of hydraulic reservoir (Figure 34, Item 5) and
secure hose in place.
Figure 34. Hydraulic Reservoir.
0086
9. Connect inlet hose (Figure 35, Item 1) and outlet hose (Figure 35, Item 2) to flowmeter (Figure 35, Item 3).
Figure 35. Flowmeter Connections.
0086