TM 5-2420-231-23-1
0086
PILOT CONTROL VALVE TEST CONTINUED
4. Remove hydraulic tank cap (Figure 34, Item 1).
5. Remove pressure testing adapter (Figure 32, Item 1) from pump EF port (Figure 32, Item 2).
Figure 32. EF Port.
0086
6. Connect flowmeter inlet (input) hose (Figure 33, Item 1) to EF port (Figure 33, Item 2).
Figure 33. Flowmeter Inlet Hose.