20
TM 5-2420-231-23-3
FIELD MAINTENANCE
-
BACKHOE SWING TOWER HOSES REPLACEMENT
02
44
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Tools and Special Tools
Materials/Parts - Continued
Tool Kit, General Mechanic's
Lockwasher (8)
0
0
O-ring (7)
0
Pan, Drain, 5 gal. Capacity (WP 0376, Item 54)
0
References
Wrench, Combination, 12 Pt, 1-1/4"
0
0
WP 0374 (Group Number 0710, 0712, 0713,
Wrench, Combination, Standard Length, 12 Pt,
0
0
0716, and 0723)
Wrench, Combination, Standard Length, 12 Pt,
Equipment Conditions
0
Backhoe stabilizers lowered
0
Wrench, Combination, Standard Length, 12 Pt,
(TM 5-2420-231-10)
0
Backhoe extended and lowered
0
(TM 5-2420-231-10)
Materials/Parts
Cap Set, Protective, Dust and Moisture
0
0
0
Estimated Time to Complete
0
Locknut (2)
0
6.0 hr
0
WARNING
Allow hydraulic system to cool before performing procedure. Hot metal parts can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills.
Failure to follow this warning may result in injury or death to personnel.
CAUTION
Plug and cap all hoses and fittings to prevent contamination. Failure to follow this caution
may result in damage to the machine.
NOTE
Tag and mark lines to aid in installation.
Note position of lines to aid in installation.
0244-1