TM 5-2420-231-23-3
0244
REMOVAL
0244
1. Remove cap from hydraulic tank (TM 5-2420-231-10).
2. Disconnect auxiliary hose (Figure 1, Item 3) from tube (Figure 1, Item 4).
3. Remove bolt (Figure 1, Item 5), washer (Figure 1, Item 6), clamp (Figure 1, Item 1), and insulator (Figure 1,
Item 2) from auxiliary hose (Figure 1, Item 3).
Figure 1. Left Auxiliary Hose Connection.
0244
4. Disconnect auxiliary hose (Figure 2, Item 5) from tube (Figure 2, Item 7).
5. Disconnect auxiliary hose (Figure 2, Item 6) from tube (Figure 2, Item 8).
6. Remove bolt (Figure 2, Item 3), washer (Figure 2, Item 4), clamp (Figure 2, Item 2), and two insulators
(Figure 2, Item 1) from auxiliary hose (Figure 2, Items 5 and 6).
Figure 2. Right Auxiliary Hose Connection.
0244