0288
ADJUSTMENT CONTINUED
6. Loosen two jamnuts (Figure 15, Item 2).
NOTE
If control towers don't lock in place, shorten cable.
If control towers don't release, lengthen cable.
7. Turn two jamnuts (Figure 15, Item 2) toward cable jacket (Figure 15, Item 3) to shorten cable.
8. Turn two jamnuts (Figure 15, Item 2) toward cable end (Figure 15, Item 1) to lengthen cable.
9. Tighten two jamnuts (Figure 15, Item 2).
Figure 15. Cable Adjustment.
0288