Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
CAPABLE IF:
SERVICE
ITEM NO. INTERVAL
PROCEDURE
Semiannually Transmission Oil s. Attach hose to sump strainer and
17
Change
secure with split flange clamps.
(Cont.)
t. Fill transmission with fresh
lubricant through fill-check pipe. Refer
package for grade and quantity of fluid
required. Install transmission level
gauge.
Operate loader with no load until
transmission oil reaches a normal
operating temperature (approximately
150 to 200F ([65 to 90C]).
v. Install transmission level gauge
and check oil level.
w. Park loader on level ground. Place
transmission in neutral leaving engine
running. Apply parking brake.
y. Check transmission oil level.
0018-21