TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
Semiannually Transmission Oil n. Push down on stem inside of pipe
17
Change
and inspect mating surface of rubber
(Cont.)
disc for excessive wear. Replace valve
assembly if necessary.
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an envi-
ronmentally compliant and low-toxic material. However, it may
be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open
flames and other sources of ignition. Failure to do so may result
in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT
exceed 15 psi (103 kPa) nozzle pressure when drying parts
cleaning components. DO NOT direct compressed air against
human skin. Make sure air stream is directed away from user
and other personnel in the area. User must wear protective
goggles or face shield.
Failure to follow these warnings may result in injury or damage
to personnel.
o. Wash valve assembly and strainer
in cleaning solvent. Remove all metal
particles from magnetic rods on
strainer. If necessary, rods may be
removed. Dry parts with compressed
air.
p. Assemble strainer onto valve
assembly.
q. Install a new gasket over strainer
and align holes with retaining plate
mounting holes.
r. Install strainer assembly in
transmission and secure in place with
bolts previously removed.