TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
Monthly
Transmission
21
WARNING
Breather
Solvent cleaning compound MIL-PRF-680 Type III is an envi-
ronmentally compliant and low-toxicity material. However, it
may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from
open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT
exceed 15 psi (103 kPa) nozzle pressure when drying parts
cleaning components. DO NOT direct compressed air against
human skin. Make sure air stream is directed away from user
and other personnel in the area. User must wear protective
goggles or face shield.
Failure to follow these warnings may result in injury or death to
personnel.
NOTE
Breather is located at top of transmission in housing.
Unscrew breather to remove and
Class III oil leak is evident.
clean it in a cleaning solvent. Dry
breather with compressed air and
install.
0018-29