TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
CAPABLE IF:
SERVICE
ITEM NO. INTERVAL
PROCEDURE
a. Place a suitable container under
Semiannually Intermediate
26
drive block to catch oil.
Drive Block Oil
Change
b. Remove oil level gauge and drain
Class III oil leak is evident.
plug.
c. Install drain plug after oil has
completely drained.
d. Fill block through level gauge hole.
work package for grade and quantity
of fluid required.
e. Install oil level gauge and check oil
level.
Figure 20. Intermediate Drive Block.
0018