Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
Semiannually Planetary Oil
c. Place suitable container below
39
Change
planetary drain plug to catch oil.
(Cont.)
d. Remove planetary drain plug.
e. After oil stops draining, install
planetary drain plug.
f. Repeat steps a through e for
opposite planetary on same axle.
g. Position planetary drain plug at
12 o'clock (Figure 31).
H100C-0111-1
Figure 31. Planetary Drain at 12 O'Clock Position.
0018
h. Fill planetary to bottom of filler hole.
work package for grade and quantity
of fluid required.
i. Install filler plug.
j. Operate loader for a short period of
time so oil can work into gears
throughout axle and planetaries
k. Check oil level and add oil
necessary to bring level up to filler
plug hole.
0018-57