TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
CAB INTERIOR
Lubricate pivot points on control
40
END OF TASK
LUBRICATION INSTRUCTIONS
00018
NOTE
Lubrication instructions contained in this PMCS are MANDATORY.
The overall view of lubrication points is located at the end of this work package. Localized
views are located, together with specific lubrication instructions, in the PMCS table.
The loader is not enrolled in the Army Oil Analysis Program (AOAP).
Refer to FM 9-207 for lubrication in arctic operation.
1. Included in this PMCS are lubrication services to be performed by Field Maintenance.
2. Lubrication intervals are based on normal operation. Lubricate more during constant use and less during inac-
tive periods. Use correct grade of lubricant for seasonal temperature expected. Refer to the KEY on next page.
3. For equipment under manufacturer's warranty, hardtime intervals shall be followed. Shorten intervals if lubri-
cants are known to be contaminated or if operation is under adverse conditions (e.g., longer than usual operat-
ing hours, extended idling periods, extreme dust).
4. Keep all lubricants in a closed container and store in a clean, dry place away from extreme heat. Keep contain-
ers covers clean and do not allow dust, dirt, or other foreign materials to mix with lubricants. Keep lubrication
equipment clean and ready for use.
0018-58