4
TM 5-3805-255-14
FIELD MAINTENANCE
-
EMERGENCY SHUTDOWN CONTROL LINKAGE REPLACEMENT
0034
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
0
0
Tool Kit, General Mechanic's, Automotive (WP
0
0
0
Materials/Parts
0
0
0
0
Battery disconnect switch in OFF position
Cotter Pin
0
Locknut
Lockwasher (2)
REMOVAL
00034
1. Remove cotter pin (Figure 1, Item 2) from ferrule (Figure 1, Item 5). Discard cotter pin.
2. Remove washer (Figure 1, Item 7) and ferrule (Figure 1, Item 5) from injector pump shut-off lever (Figure 1,
Item 1).
3. Remove locknut (Figure 1, Item 3), washer (Figure 1, Item 4), and ferrule (Figure 1, Item 5) from emergency
shutdown control cable (Figure 1, Item 6). Discard locknut.
Figure 1. Emergency Shutdown Control Cable.
0034
0034-1