TM 5-3805-262-2011-2. RETURN-TO-DIG CONTROL MAINTENANCE (CONT)CLEANING AND INSPECTIONDry cleaning solvent P-D-680 used to clean parts is toxic and flammable.W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t eda r e a . A v o i d c o n t a c t w i t h s k i n , e y e s a n d c l o t h e s a n d d o n ’ t b r e a t h ev a p o r s .Do not use near open flame or excessive heat and don’t smokew h e n u s i n g i t . F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s i n j u r y . I f y oub e c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c ala t t e n t i o n i m m e d i a t e l y . I f c o n t a c t w i t h s k i n o r c l o t h e s i s m a d e , f l u s hw i t h l a r g e a m o u n t s o f w a t e r .If contact with eyes is made, wash eyeswith water and get medical aid immediately.a .b .c .d .Clean all parts using cleaning solvent P-D-680. Dry using clean cloths .Inspect actuating rod for cracks, breaks, or bent condition. Replace if any ofthese conditions are seen.Check guide rod (11) for dents or bent condition; replace if any of the aboveare seen. Insert actuating rod into guide rod and check that actuating rodmoves freely without binding in guide rod. Replace both parts if actuating roddoes not move freely or if binding is felt.Check remaining parts for cracks, breaks, dents, distortion, deformation, ordamaged or stripped threads. Replace as necessary.11-14