TM 5-3805-262-2011-2. RETURN-TO-DIG CONTROL MAINTENANCEThis task covers removal, cleaning, inspection, installation, and adjustment of re-turn-to-dig control located on right bucket tilt cylinder assembly. The return-to--dig control has two functions:(1) to return the bucket spool in the control valveassembly to its neutral position from crowd position of the bucket; and (2) indicatebucket position.TOOLS: No. 1 Common Organizational Maintenance Tool KitFixed open end wrench setSocket wrench set, 3/8 inch driveMATERIALS/PARTS: Clean cloths (Appendix C, item 1)Cleaning solvent P-D-680 (Appendix C, item 2)NOTEPRELIMINARY PROCEDURE: Return-to-dig micro switch disconnected and re-moved (page 5-68).11-12