TM 5-3805-262-20
11-2. RETURN-TO-DIG CONTROL MAINTENANCE (CONT)
INSTALLATION (SHEET 2 OF 2)
e. Position two clamps (7) on rod end of cylinder assembly.
f. Loosely install two capscrews (6), lock washers (5), and nuts (4).
g. Insert actuating rod (3) through top center of clamps (7) and into guide rod .
h. Install clevis pin (2) through clamps (7) and actuating rod (3) eye.
i . I n s t a l l c o t t e r p i n ( 1 ) a n d b e n d.
j. Reinstall return-to-dig micro switch (page 5-72).
k. Adjust return-to-dig control (page 11-17).
11-16