TM 5-3805-262-2011-3. LINES AND FITTINGS MAINTENANCE (CONT)a. Hydraulic Pump to Control Valve Assembly( c o n t ) .INSTALLATION (SHEET 2 OF 4)( 3 ) I n s t a l l U - b o l t ( 3 0 ) t o s e c u r e t u b e ( 2 4 ) t o b r a c k e t . I n s t a l l a n d t i g h t entwo lock washers (29) and nuts (28).( 4 ) I f n e c e s s a r y , install connector (27), coupling (26) and cap (25) in tube(24) port.(5) Route hose (13) between tube (24) and control valve.( 6 ) C o n n e c t h o s e ( 1 3 ) t o t u b e ( 2 4 ) ; t i g h t e n t u b e f i t t i n g s e c u r e l y .(7) Position clamps (23 and 21). Secure by installing and tightening capscrew(22), lock washer (20), and nut (19).(8) Install capscrew (18) through clamp (23) then position spacer (17) oncapscrew.(9) Position hose (13) on clamp (23) and install clamp (16). Install andtighten lock washer (15) and nut (14).11-22