TM 5-3805-262-20
3-25. HYDRAULIC SYSTEM TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3 . BUCKET TILT CYLINDER ASSEMBLIES OPERATION SLUGGISH OR POOR (ALL OTHER CYLINDERS
OPERATE PROPERLY) (Cont).
S t e p 1 . ( C o n t ) .
Clevis should move 0.44 inch approximately.
Tell assistant to place BUCKET control lever in NEUT. position, then
move it to DUMP position while you measure travel of clevis from
NEUT. to DUMP position.
Clevis should move 0.44 inch approximately.
a. If measurement is not 0.44 inch approximately, notify next
higher maintenance level to adjust control valve assembly
l i n k a g e.
b. If measurement is 0.44 inch, go to step 2 below.
3-179