TM 5-3805-262-203-25. HYDRAULIC SYSTEM TROUBLESHOOTING (CONT) MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION4. BUCKET DOES NOT RETURN TO DIGGING POSITION.Step 1.Check adjustment of return-to-dig actuating rod (page 11-17) .a. If adjustment is not okay, adjust (page 11-17).b. If adjustment is okay, go to step 2 below.Step 2.Start engine and operate at idle speed.Place LIFT ARM control lever in RAISE position until bucket is atmaximum height,then place in NEUT. position.Place BUCKET control lever in DUMP position.Press 5 ampere circuit breaker on right instrument panel.Place BUCKET control lever in CROWD position and LIFT ARM controllever in FLOAT position.Check that bucket rolls back and lowers to ground.a. If bucket is not flat on ground or is not at correct diggingangle, go to step 5 below.b. If 5 ampere circuit breaker blew, try to determine if it blewimmediately or when bucket was lowering. If circuit breaker blewimmediately, problem is short circuit in hydraulic filterswitches or warning lamp circuitry. Perform resistance checks ofcircuit to isolate defective part. If circuit breaker blew whenbucket was lowering to ground; go to step 3 below.c. If bucket is flat on ground or is at correct digging angle,problem was momentary shortopen.Shut off engine.c i r c u i t c a u s i n g c i r c u i t b r e a k e r to3-182