TM 5-3805-262-342-7.STARTERTROUBLESHOOTING(CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1. STARTER DOES NOT CRANK (Cont).Step 5.Inspect armature commutator bars for dirt or corrosion.Check for bad contact between brushes and commutator bars.a. If commutator bars are dirty or corroded, clean or replace arma-ture. Reassemble starter (page 3-240).b. If commutator bars check okay, go to step 6 below.Step 6.Inspect brush springs and brushes for damage or wear (page 3-236).a. Replace broken brush springs or worn brushes and reassemblestarter (page 3-240).b. If brush springs and brushes check okay, go to step 7 below.Step 7.Inspect insulators (36) (page 3-231) for wear or damage.a. Replace defective insulators and reassemble starter (page3-240) .b. If insulators check okay, go to step 8 below.Step 8.Check that pole shoesa. If pole shoes arewrench.b. If pole shoes areare tight (step (8), page 3-242).loose, tighten screws using hand-impacttight, go to step 9 below.Step 9.Test armature (page 3-236).a. Replace defective armature and reassemble starter (page 3-240).b. If armature checks okay, go to step 10 below.Step 10.Test plate and frame assembly (page 3-234).a. Replace defective plate and frame assembly and reassemblestarter (page 3-240).b. If plate and frame assembly checks okay, test field coil (page3-235). Replace field coil and reassemble starter (page 3-240).2-81