TM 5-3805-262-34
Dry cleaning solvent P-D-680 used to clean
Wear protective goggles and gloves and
parts is toxic and flammable.
use only in a well ventilated
area. Avoid contact with skin, eyes and clothes and donut breathe
vapors. Do not use near open flame or excessive heat and dont smoke
when using it. Failure to do so could cause serious injury. If you be-
come dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush
with large amounts of water. If contact with eyes is made, wash eyes
with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi. Use
only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc). Failure to do so could cause serious
injury to eyes and possible blindness. If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention
immediately.
(a) Clean oil suction tube (1) using cleaning solvent P-D-680. Agitate tube
screen in cleaning solvent and remove blockage and residue using com-
pressed air.
(b) Clean exterior of oil pump (5) using clean cloths moistened with clean-
ing solvent P-D-680. Dry using clean cloths.
(c) Clean all other parts using cleaning solvent P-D-680. Dry using clean
cloths.
INSPECTION
NOTE
Replace an item if inspection indicates need for replacement.
(a) Inspect oil suction tube (1) for cracks, kinks, distortion, or
threads. Inspect screen for tears, blockage, and deformation.
(b) Inspect oil pump (5) for cracks, nicked or missing gear teeth,
damaged
or other
damage. Forward defective oil pump to general support maintenance for
repair.
(c) Inspect all other parts for cracks, distortion, or thread damage.
3-93