3-2. FUEL SYSTEM MAINTENANCE (CONT)
e. Fuel Injection Governor (Cont).
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
Wear protective goggles and gloves and use only in a well ventilated
area. Avoid contact with skin, eyes and clothes and dont breathe
vapors. Do not use near open flame or excessive heat and dont smoke
when using it. Failure to do so could cause serious injury. If you be-
come dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush
with large amounts of water. If contact with eyes is made, wash eyes
with water and get medical aid immediately.
(1)
Scrape gasket material and sealing compound from mating surfaces of hous-
ing (30), governor cover (77), and fuel injection pump using putty knife.
Remove residue using clean cloth moistened with cleaning solvent P-D-680.
Compressed air used for cleaning purposes will not exceed 30 psi. Use
only with effective chip guarding and personal protective equipment
(goggles/shield, gloves, etc). Failure to do so could cause serious
injury to eyes and possible blindness.
If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention
immediately.
(2)
Clean all metal parts using cleaning solvent P-D-680. Dry using com-
pressed air.
3-176