TM 5-3805-262-343-2. FUEL SYSTEM MAINTENANCE (CONT)e. FuelInjectionGovernor (Cont).Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.Wear protective goggles and gloves and use only in a well ventilatedarea. Avoid contact with skin, eyes and clothes and don’t breathevapors. Do not use near open flame or excessive heat and don’t smokewhen using it. Failure to do so could cause serious injury. If you be-come dizzy while using cleaning solvent, get fresh air and medicalattention immediately. If contact with skin or clothes is made, flushwith large amounts of water. If contact with eyes is made, wash eyeswith water and get medical aid immediately.(1)Scrape gasket material and sealing compound from mating surfaces of hous-ing (30), governor cover (77), and fuel injection pump using putty knife.Remove residue using clean cloth moistened with cleaning solvent P-D-680.Compressed air used for cleaning purposes will not exceed 30 psi. Useonly with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc). Failure to do so could cause seriousinjury to eyes and possible blindness.If you hurt your eyes or if aforeign object is blown into your eyes, seek medical attentionimmediately.(2)Clean all metal parts using cleaning solvent P-D-680. Dry using com-pressed air.3-176