TM 5-3805-262-343-5. STARTER REPAIR (CONT) REASSEMBLY (SHEET 5 OF 6)NOTEDon’t connect electrical lead (3) tosolenoid (10) terminal. Electricallead will be connected to solenoidafter pinion clearance is checked.ai.aj.(1)( 2)3-248Install lock washer and nuton solenoid MTR terminal.Tighten nut to 20 to 25lb-ft .Check starter drive pinion clearance:Connect two 12 volt batteries and remoteMTR terminals as shown.starter switch to solenoid S andPush in and hold button on remote starter switch. The starter drive as-sembly will slide into start position, and will remain in start positionuntil button on remote starter switch is released.