TM 5-3805-262-34
3-5. STARTER REPAIR (CONT)
REASSEMBLY (SHEET 5 OF 6)
NOTE
Dont connect electrical lead (3) to
solenoid (10) terminal. Electrical
lead will be connected to solenoid
after pinion clearance is checked.
ai.
aj.
(1)
( 2)
3-248
Install lock washer and nut
on solenoid MTR terminal.
Tighten nut to 20 to 25
lb-ft .
Check starter drive pinion clearance:
Connect two 12 volt batteries and remote
MTR terminals as shown.
starter switch to solenoid S and
Push in and hold button on remote starter switch. The starter drive as-
sembly will slide into start position, and will remain in start position
until button on remote starter switch is released.