TM 5-3805-262-343-6. WIRING HARNESSES MAINTENANCE (CONT)d. CabUpperWiringHarness(Cont).INSTALLATION (SHEET 1 OF 4)NOTESpray all terminals and contacts with electrical cleaner and allow toair dry before making connections.(1)(2)(3)(4)(5)Using electrical tape, tape new cab upper wiring harness three wipermotor wires to a 16 feet long piece of wire. This wire will be used as afish wire to fish new wiring harness through left front and rear posts.Using electrical tape, tape all cab upper wiring harness branches to mainbranch. This will make it easier to pull harness through rectangular holein cab rear wall and up through left rear post.Guide cab upper wiring harness through rectangular hole in cab wall andthrough left rear post while assistant slowly pulls it using fish wiretaped to harness. Tell assistant to pull on fish wire from top of leftrear post not at front windshield.When cab upper wiring harness is completely through top of left rearpost, remove all electrical tape from branches except branch containingthree wiper motor wires. Push harness connector firmly into its rectangu-lar mounting cutout in cab wall until it snaps into position.At front windshield, left post, tell assistant to slowly pull fish wirethrough hole in post while you guide harness branch down into post.3-300