TM 5-3805-262-34
INSTALLATION (SHEET 2 OF 4)
(6)
(7)
(8)
(9)
When cab upper wiring harness three wiper motor wires are through hole,
remove electrical tape from fish wire. Discard fish wire. Pull harness
wiper motor wires over to windshield wiper motor.
NOTE
Spray all exposed terminals with electrical sealer.
Connect cab upper wiring harness black-yellow wire spade terminal to
wiper motor P terminal; orange-blue wire spade terminal to L terminal;
and tan-black wire spade terminal to H terminal. Do this by grasping
spade terminal in fingers, alining with motor terminal, and firmly
pushing onto motor terminal.
At cab ceiling, route cab upper wiring harness brown-white wire terminal
and yellow-black terminal to defogger and cab dome light mounting area.
Route cab upper wiring harness blue wire terminal to left turn signal
lamp assembly wire lead. Connect harness blue wire terminal to lamp
assembly terminal. Do this by grasping terminals with fingers, alining,
and firmly pushing together.
3-301