TM 5-3805-262-34INSTALLATION (SHEET 2 OF 4)(6)(7)(8)(9)When cab upper wiring harness three wiper motor wires are through hole,remove electrical tape from fish wire. Discard fish wire. Pull harnesswiper motor wires over to windshield wiper motor.NOTESpray all exposed terminals with electrical sealer.Connect cab upper wiring harness black-yellow wire spade terminal towiper motor P terminal; orange-blue wire spade terminal to L terminal;and tan-black wire spade terminal to H terminal. Do this by graspingspade terminal in fingers, alining with motor terminal, and firmlypushing onto motor terminal.At cab ceiling, route cab upper wiring harness brown-white wire terminaland yellow-black terminal to defogger and cab dome light mounting area.Route cab upper wiring harness blue wire terminal to left turn signallamp assembly wire lead. Connect harness blue wire terminal to lampassembly terminal. Do this by grasping terminals with fingers, alining,and firmly pushing together.3-301