Home
Download PDF
Order CD-ROM
Order in Print
INSTALLATION (SHEET 3 OF 4) - TM-5-3805-262-34_456
e. Cab Lower Wiring Harness
TM-5-3805-262-34 Loader Scoop Type DED 4x4 Articulated Frame Steer 2-1/2 Cubic Yard (J.I. Case Model MW24C) Manual
Page Navigation
437
438
439
440
441
442
443
444
445
446
447
TM 5-3805-262-34
INSTALLATION (SHEET 4 OF 4)
(15) At rear of cab, just behind heater console
, connect cab console wiring
harness connector to cab upper wiring harness connector mounted on cab
wall. Be sure that tabs on console wiring harness connector engage cab
upper wiring harness connector ears.
(16) Connect battery ground cable (refer to TM 5-3805-262-20).
(17) Turn ignition key switch to on position.
Test cab upper wiring harness
(refer to TM 5-3805-262-20).
(18)
Put rear cover in
position in rear of
cab. Secure using
ten washers and
screws.
3-303