TM 5-3805-262-343-13. FLOWMETER TESTS The following tests will measure volume, pressure, and temperature of hydraulic oil.Test no. 1 determines if there are any problems between hydraulic reservoir andsteering section of hydraulic pump, and efficiency of hydraulic pump steeringsection.Test no. 2 indicates if there are any problems in the steering circuit.Perform these tests anytime you have problems with the steering system or yoususpect problems may exist.TOOLS: No. 1 Common Organizational Maintenance Tool KitFixed open end wrench setFlowmeter (FSCM 45225 PN CAS-10280)Flowmeter fitting kit (FSCM 45225 PN CAS-10106)Plugs, twoCapMATERIALS/PARTS: Clean cloths (Appendix C, item 1)Cleaning solvent P-D-680 (Appendix C, item 2)TEST NO. 1 - HYDRAULIC PUMP STEERING SECTION (SHEET 1 OF 5)Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.Wear protective goggles and gloves and use only in aarea. Avoid contact with skin, eyes and clothes andvapors. Do not use near open flame or excessive heatwhen using it. Failure to do so could cause seriousbecome dizzy while using cleaning solvent, get freshattention immediately. If contact with skin or clotheswith large amounts of water. If contact with eyes iswith water and get medical aid immediately.well ventilateddon-t breatheand don’t smokeinjury. If youair and medicalis made, flushmade, wash eyesa.Using clean cloth moistened with cleaning solvent clean all dirt and greasefrom quick disconnect coupling (1) at pump outlet.3-500