TM 5-3805-262-34
TEST NO. 2 - STEERING CIRCUIT AND RELIEF VALVE (SHEET 1 OF 5)
a.
NOTE
If you have just completed test no. 1
, go to step i below, otherwise go
to step a below.
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
Wear protective goggles and gloves and use only in a well ventilated
area. Avoid contact with skin,
eyes and clothes and dont breathe
vapors. Do not use near open flame or excessive heat and dont smoke
when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush
with large amounts of water.
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
Using clean cloth moistened with
cleaning solvent clean all dirt
and grease from quick disconnect
coupling (1) at pump outlet.
b.
Open access door in front of loader.
c.
Loosen and remove hydraulic reser-
voir fill cap (2) from hydraulic
reservoir.
3-505