TM 5-3805-262-34
SHEET 3 OF 4
(6) At control valve assembly, remove
acorn nut (4) and washer (5).
(7) Loosen nut (6).
(8)
(9)
Turn adjusting screw (7) clockwise
to increase pressure setting,
counterclockwise to decrease pres-
sure setting.
Tighten nut (6) using a screw-
driver to hold adjusting screw so
as not to change adjustment.
3-619