TM 5-3805-290-23-1
TRANSMISSION TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
TRANSMISSION CLUTCH FILL CALIBRATION - CONTINUED
2.
Calibration Procedure.
a.
Connect MSD equipped with ET Software and communication adapter to perform this test procedure (WP 0006
b.
Open software program. Select transmission ECM for machine being calibrated.
c.
Select "Service" menu to begin calibration procedure. Then select "Calibrations". Second menu will be displayed.
Select "Transmission Fill Calibration" from second menu.
427-B0920
d.
Next screen is initial calibration screen. Once "Transmission Fill Calibration" has been selected, screen displays
instructions for calibration. Top display area displays status parameters monitored during calibration. Middle dis-
play area displays information about status of calibration. Display area on bottom will display conditions for setup
and calibration.
0014 00-4