TM 5-3805-290-23-1
HYDRAULIC SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0017 00
RELIEF VALVE (LINE) TEST AND ADJUSTMENT - CONTINUED
f.
Remove cap (13). Loosen locknut (14). Turn
adjusting screw (15) clockwise to increase relief
valve setting.
g.
Turn adjusting screw (15) counterclockwise to
decrease relief valve setting.
h.
After adjusting screw (15) is adjusted, tighten
locknut (14) to 15 2 lb-ft (20 3 Nm).
i.
Install cap (13).
427-B0966
j.
k.
Observe pressure gage and move control lever to ENGAGED position.