TM 5-3805-290-23-2
VALVE COVER AND CRANKCASE VENT REPLACEMENT - CONTINUED
0024 00
VALVE COVER REMOVAL - CONTINUED
00024 00
5.
Remove bolt (5) and bracket (6) from valve cover (3)
and position bracket aside.
427-B2001
VALVE COVER CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic material.
However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-ventilated
areas. Keep away from open flames and other sources of ignition. Failure to do so may result in injury or
death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when dry-
ing parts with compressed air. DO NOT direct compressed air against human skin. Make sure air stream is
directed away from user and other personnel in the area. To prevent injury, user must wear protective goggles
or face shield. Failure to follow this warning may result in injury to personnel.
1.
Remove all gasket material from mating surfaces.
2.
Clean all parts (except hose) and mating surfaces with solvent cleaning compound.
3.
Dry parts with compressed air.
4.
Inspect all parts for damage, wear, pitting, cracks, or corrosion and replace if necessary.
0024 00-3